HK-K17 - February 6th, 2009
Notes
- Cool heater - damper and ashbox door had been left open from yesterday's burn
- White Birch, 20% moisture
- 12 pieces, 4.5 lbs kindling, 64.4 lbs total
- Smaller pieces, stacked front to back. Kindling on top.
- No CO spike at the beginning, a very significant result.
- Data problems with Testo analyzer, see notes below gas graph.
- Ashbox door closed, air inlet left open 50% to simulate a slightly leaky heater. Damper left open.
- Cold air bypass closed.
- 0.93 g/kg PM (Condar)
- 13.9 g/kg CO
- 76.7 % overall efficiency
- Very good numbers, but not reliable due to data loss. See notes with gas graph.
Animation
Flue Gas
- Equipment problems. First 18 minutes missing, data loss due to power failure. Values estimated from memory.
- Testo malfunction between 42 minutes and 80 minutes - data interpolated between adjacent values.
-
Ashbox door was closed at 101 minutes, and air control closed 50%. Only gas data up to 101 minutes was used to calculate efficiency and emissions.
Opacity
No image available.
Statistics
Good numbers, but not reliable, see notes on gas graph, above. However, a very interesting result for small wood, due to the absence of the usual CO spike at the beginning.
Fuel stack
Resources
- Excel Data File: Unavailable
- Condar Spreadsheet + Fueling Excel Data File: Condar-HKK-17.xlsm




No Comments