Lopez Labs

The biggest part of the library, by far, and probably always will be. 

About Lopez Labs

Jerry Frisch with his clean burning Frisch Rosin masonry fireplace system (Norbert Senf on the ...

Tests

HK-G00 to HK-G08 - February 1st, 2006 to February 13th, 2006

Feb 01/06 - Preliminary Test This test was a dry run. The heater was not preheated. Test fue...

HK-G09 - February 16th, 2006

Test HK-G09 February 16/06 Cold heater Cold fuel Small load Test HK-G09 F...

HK-G10 - February 17th, 2006

Test HK-G10February 17/06 Unrestricted air (ashbox door open) Repeat of test G-07 / HK-G07 ...

HK-G11 - February 18th, 2006

Test HK-G11February 18/06 Restricted air (ashbox door closed, air control open) Large wood, l...

HK-G12 - February 19th, 2006

Test HK-G12February 19/06 Restricted air (ashbox door closed, air control open) Large wood, v...

HK-G13 - February 20th, 2006

Test HK-G13February 20/06 Side kindling - very low opacity burn with no spike. Small wood, me...

HK-G14 - February 21st, 2006

A repeat of the "side burn" from yesterday, except with a large load of large, cold wood.Again, n...

HK-G14 - Update from April 3rd, 2006

After the Feb 21 test, about 25 repeat burns were observed anecdotally in a heater with a similar...

HK-H01 - Unknown

Unfortunately, no records of what Test HK-H01 was, survive. 

HK-H02 - February 16th, 2007

Notes Dry run, white birch. Left side ignition. Data to follow later [Editor's note: The dat...

HK-H03 - February 17th, 2007

Notes Large sized maple. 20% moisture 6 pieces, stacked 222. Left side ignition. Animated G...

HK-H04 - February 18th, 2007

Notes Medium sized maple. 20% moisture 8 pieces, stacked 2231. Left side ignition. Animated...

HK-H05 - February 19th, 2007

Notes Large sized maple. 19% moisture 7 pieces, stacked 2221 Grate open, ashbox door open f...

HK-H06 - February 20th, 2007

Notes Small sized maple  19% moisture 9 pieces, stacked 22221 Grate open, ashbox door close...

HK-H07 - February 21st, 2007

Notes Large sized maple 19% moisture 7 pieces, stacked 2221 Grate open, ashbox door closed....

HK-H08 - February 22nd, 2007

Notes Description to follow  Animated Gif below, taken at 2 minute intervals. White Birch. ...

HK-H09 - February 25th, 2007

Notes Mixed. 19% moisture (estimated) 7 pieces, stacked 2221. Left side ignition. Cold heat...

HK-H10 - February 28th, 2007

Notes Mixed size maple. 19% moisture (estimated)  6 pieces, stacked 222. Left side ignition. ...

HK-H11 - March 1st, 2007

Notes Small maple. 19% moisture (estimated) 9 pieces, stacked 3221. Left side ignition. Cold...

HK-H12 - March 3rd, 2007

Notes Crib test. Top two layers are 4x4 spruce, 15% moisture, 4 pc per layer. See stacking pho...

HK-H13 - March 4th, 2007

Notes Crib test. Top two layers are 4x4 spruce, 18% moisture, 4 pc per layer. See stacking pho...

HK-H14 - March 5th, 2007

Notes Mixed size maple. 19% moisture (estimated). 60 lbs  7 pieces, stacked 2221. Left side i...

HK-H15 - March 6th, 2007

Notes Small maple. 19% moisture (estimated). 54 lbs  8 pieces, stacked 2231. Right side ignit...

HK-H16 - March 7th, 2007

Notes Very small maple - simulation of ASTM crib (see HK-H13) . 19% moisture (estimated). 39 l...

HK-H17 - March 8th, 2007

Notes Very small maple - simulation of ASTM crib (see HK-H13) . 19% moisture (estimated). 47.5...

HK-H18 - March 10th, 2007

Notes Large maple. Medium warm heater. 49lbs Previous fire: 36 hours. Grate air closed. Ashb...

HK-H19 - March 10th, 2007

Notes Large maple. Hot heater. 50lbs Previous fire: 10 hours. Grate air open. Ashbox door cl...

HK-H20 - March 11th, 2007

Notes Small to medium maple. Warm heater. 54.2 lbs Previous fire: 24 hours. Grate air open. ...

HK-I01 - October 10th, 2007

Notes First test of FGM (Free Gas Movement) series White birch, 20% moisture Cold heater, co...

HK-I02 - October 11th, 2007

Notes White birch, 20% moisture  Previous fire: 24 hours. Repeat run of HK-I01, with warm he...

HK-I03 - October 12th, 2007

Notes White birch, 24% moisture Previous fire: 24 hours. Very large pieces, still with some ...

HK-I04 - October 13th, 2007

Notes White birch, 20% moisture  Previous fire: 24 hours. Repeat with large fuel, except one...

HK-I05 - October 14th, 2007

Notes White birch, 20% moisture  Previous fire: 20 hours. Medium to large wood, large load o...

HK-I06 - October 15th, 2007

Notes White birch, 20% moisture  Previous fire: 24 hours. Small wood, 12 pieces. 2 lbs kindl...

HK-I07 - October 16th, 2007

Notes White birch, 20% moisture  Previous fire: 24 hours. Medium wood, evenly sized, 8 piece...

HK-J01 - January 4th, 2008

Notes White birch, 20% moisture, 51 lbs. Cold heater, cold wood Medium wood, 8 pieces, 2.1 l...

HK-J02 - January 5th, 2008

Notes Mixed hardwood, 16% moisture, 61 lbs Previous fire: 24 hours Large wood, 8 pieces, 2.5...

HK-J03 - January 11th, 2008

Notes Highest piece count (cordwood) of 30 run series Small white birch, 20% moisture, 51 lbs...

HK-J04 - January 12th, 2008

Notes Hard maple, medium pieces, 16% moisture, 56.2 lbs 8 pieces, 3 lbs kindling C...

HK-J05 - January 13th, 2008

Notes Hard maple, medium pieces, 16% moisture, 52 lbs 8 pieces, 3.6 lbs kindling Cold fuel, ...

HK-J06 - January 14th, 2008

Notes White birch, medium pieces, 20% moisture, 62.1 lbs 10 pieces, 3.5 lbs kindling Cold fu...

HK-J07 - January 15th, 2008

Notes White birch, large pieces, 21% moisture, large load 79.1 lbs 8 pieces, 4.5 lbs kindling...

HK-J08 - January 16th, 2008

Notes Lowest PM number of 30 run series Hard maple, medium and large pieces, 16% moisture, la...

HK-J09 - January 21st, 2008

Notes White birch, large and small pieces, 20% moisture, medium load 48.7 lbs 9 pieces, 3.25 ...

HK-J10 - January 23rd, 2008

Notes Maple, large pieces, 16% moisture, large load 70 lb. 6 pieces, 2.5 lbs kindling Cold f...

HK-J11 - January 26th, 2008

Notes White birch, small pieces, 19% moisture, medium load 41 lbs 12 pieces, 1.8 lbs kindling...

HK-J12 - January 27th, 2008

Notes Highest PM number of 30 run series Highest Surface/Volume of 30 run series Lowest mois...

HK-J13 - January 28th, 2008

Notes ASTM fuel crib supplied by OMNI, 10% moisture 44.6 lbs 12 pieces, 2 lbs kindling Room ...

HK-J14 - January 29th, 2008

Notes Large and medium maple, 16% moisture, 65 lbs, 8 pieces, 5.5 lbs kindling Warm heater, ...

HK-J15 - January 30th, 2008

Notes Large and small maple, 16% moisture, 53 lbs, 9 pieces, 3.3 lbs kindling Warm...

HK-J16 - February 2nd, 2008

Notes Highest moisture of 30 run series Highest kindling weight of 30 run series Wet har...

HK-J17 - February 3rd, 2008

Notes Mixed hardwood, 21% moisture, 64 lbs 8 pieces, 3.2 lbs kindling Warm heater, warm fuel...

HK-J18 - February 4th, 2008

Notes White birch, 19% moisture, 55 lbs 13 pieces, 1.5 lbs kindling Warm heater, warm fuel, ...

HK-J19 - February 6th, 2008

Notes Maple, 17% moisture, 55 lbs Large and small mixed, 8 pieces, 1.5 lbs kindling ...

HK-J20 - February 11th, 2008

Notes Maple, 17% moisture, 58 lbs Large pieces, 8 pieces, 4.2 lbs kindling Cold heater (50F ...

HK-J21 - February 13th, 2008

Notes White birch, 20% moisture, 65 lbs Large pieces, 8 pieces, 3.5 lbs kindling Cold heater...

HK-J22 - February 14th, 2008

Notes White birch, 20% moisture, 59.3 lbs Large and small pieces, 10 pieces, 3.0 lbs ki...

HK-J23 - February 15th, 2008

Notes Lowest CO of 30 run series White birch, 20% moisture, 70.5 lbs Very large pieces, smal...

HK-J24 - February 16th, 2008

Notes White birch, 20% moisture, 61.3 lbs Large pieces, smaller on top, 8 pieces Stack slope...

HK-J25 - February 17th, 2008

Notes Maple, 17% moisture, 69.6 lbs Large pieces, smaller on top, 8 pieces Stack sloped towa...

HK-J26 - February 18th, 2008

Notes Maple, 17% moisture, 68.5 lbs Medium pieces, all round pieces, smaller on top, 10 piece...

HK-J27 - February 20th, 2008

Notes Lowest instantaneous CO/CO2 ratio of 30 run series White birch, 20% moisture, 70.0 lbs ...

HK-J28 - February 21st, 2008

Notes Highest CO of 30 run series Maple, 16% moisture, 50.3 lbs Small pieces, smaller on...

HK-J29 - February 22nd, 2008

Notes Lowest surface/volume (largest pieces) of 30 run series Mixed hardwood, 18% moisture, 7...

HK-J30 - February 23rd, 2008

Notes This is the last run in the HK-J series. Largest fuel load of 30 run series. Maple, 18...

Data Analysis, HK-J series, 30 Condar runs

HK-K01 - January 8th, 2009

Notes This is the first run in the HK-K series. Cold heater, warmup run. Aim is to run a set ...

HK-K02 - January 9th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data w...

HK-K03 - January 10th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K04 - January 11th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K05 - January 12th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K06 - January 13th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K07 - January 14th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K08 - January 15th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K09 - January 16th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K10 - January 17th, 2009

Notes Warm heater. Surface temperatures are being tracked for damper comparisons, and data wil...

HK-K11 - January 18th, 2009

Notes Warm heater.  Air closed at 112 minutes. Damper left open. Very staged burn, with even...

HK-K12 - January 19th, 2009

Notes Warm heater Air closed at 115 minutes. Damper cut back. Closed at 275 minutes. Somewha...

HK-K13 - February 2nd, 2009

Notes Cold heater White Birch, 20% moisture 6 pieces, 4.5 lbs kindling, 63.0 lbs t...

HK-K14 - February 3rd, 2009

Notes Warm heater White Birch, 20% moisture 6 pieces, 4.5 lbs kindling, 62.3 lbs total Two ...

HK-K15 - February 4th, 2009

Notes Warm heater White Birch, 20% moisture 8 pieces, 4.5 lbs kindling, 60.6 lbs total Smal...

HK-K16 - February 5th, 2009

Notes Warm heater White Birch, 20% moisture 9 pieces, 4.5 lbs kindling, 63.6 lbs total Smal...

HK-K17 - February 6th, 2009

Notes Cool heater - damper and ashbox door had been left open from yesterday's burn White Bir...

Test Series

WoodSim and other software

A whole house simulator that includes woodburning combustion devices, written for the Research Di...

EVERYTHING BELOW THIS LINE MAY BE MOVED OR REORGANIZED IN THE FUTURE

Repeatability of Cordwood Combustion Particulate Measurements

PowerPoint: Condar.pptx PDF: Condar.pdf

Data Analysis - 185 Masonry Heater Tests from 2006 - 2019

Download the PDF: Data Summary190225-2.pdf Excerpts: Here's another run at a summary based on t...

January 2023 Heater Calculator update by Damien Lehmann, AFPMA

2018 Next Generation Woodstove Design Challenge

(Photo credit: Jim Schalles) The MHA Tech Committee organized a 5 person testing team to s...

Heater Calculator update by Damien Lehmann, AFPMA

Repeatability of Cordwood Combustion Particulate Measurements

PowerPoint: Repeatability of Cordwood Combustion Particulate Measurements.pptx PDF: Repeatabilit...

Testing an OekoSolve Electrostatic Precipitator at the 2018 Stove Design Challenge

Pellet stove emissions comparison testing with EPA Method 5G

Photos by Norbert Senf As part of the Pellet Stove Design Challenge, we are asking "how repeatab...

Austrian Eco Firebox Testing

Background The heater in the lab has a replaceable firebox liner. The standard liner of firebr...

2018 MHA Research Heater Tests - "Substantially Similar" Study

Heater Comparison Testing at Ortner Company in Austria

URL: http://stovemaster.com/html_en/testing_at_ortner_gmbH_2014.html Backup PDF: STOVEMASTER - T...

Powerpoint: Repeatability of Wood Combustion Particulate Measurements

Data summary for 87 runs (2008 - 2010)

PDF: 2010 testing summary3.pdf

Heater Field Testing Workshop at 2017 MHA Meeting

Manufactured Heater Test Method Exploratory Testing

2017 MHA Research Heater Tests - Cordwood Repeatability

Decombustion Theory

Experimental Heater Testing Workshop, Wildacres 2016

2016 MHA Research Heater Tests

Research Heater build and instrumentation

Calibration of Heater Simulation Software for Potential EPA Certification

Condar Correlation Study against EPA Method 5G

2015 Ontario Stove Testing Camp

Eco Firebox Testing in France

Heater Comparison Testing at Ortner Company in Austria

Next Generation Woodstove Design Challenge at Brookhaven National Laboratory

Toronto Fireplace Retrofit Project

2014 Test Series

Field Testing the Norcore 5 run heater at Wildacres

Austrian Eco-firebox testing at Masonry Stove Builders

Fuel crib repeatability testing

Condar comparison testing at OMNI-Test

Condar comparison testing at Brookhaven National Laboratory

Wood Stove Decathlon 2013

2010 Test Series

Bell Experiments with a Contraflow Heater

Lopez Labs Conference 2010

Evaluating a Testo 308 Digital Smoke Spot Meter

Bell Construction and Testing Workshop

Rocket-Bell Experiments

Alaska Fireplace Retrofit Project

Condar dilution tunnel particulates data summary (2008-9, 67 runs)

2009 Test Series

Experimental Masonry Hydronic Heating Workshop

Masonry Heater Emissions Testing at Shawville, 2008

Burning Pellets in a Masonry Heater

Comparison of 4 Condar portable dilution tunnels - Fairbanks, Alaska, 2007

Free Gas Movement - Shawville 2007

2006 - 2007 Contraflow Tests at Shawville

Technical Assessment of Hi-mass Masonry Heaters and Integrated Water Loop

Bell heater testing - Alex Chernov, 2007

Bell heater testing - Wildacres 2006

Bell heater testing - Toronto 2006

Fuel Crib Testing, February, 2005

Crib Testing at Lopez Lab Co-Operative 2008-2014 - all test runs

Clearance to Combustibles Testing, MHA Annual Meeting, 2001

Clearance to Combustibles Testing, Shawville, April, 2000

1997 Heater Combustion Tests

Low Emissions Residential Cordwood Combustion in High Mass Appliances - Recent Research and Results

A Comparison of Fireplace Emissions Testing Methods

Very Low Emissions Cordwood Combustion in High Burn Rate Appliances - Early Results with Possible Implications

Air Requirements and Related Parameters for Masonry Heating Systems

Summary of 101 Masonry Heater Emissions Tests

NYSERDA Biomass Heating R&D Program Case Studies

Masonry Heater White Paper

MHA Position Paper

Short Course on Masonry Fireplace and Masonry Heater Emissions Testing Method and Combustion Design

Short Course on Masonry Heating Systems

Review - particulate emissions from wood burners in New Zealand

An Investigation of the Variability of Particulate Emissions from Woodstoves in New Zealand

Emission Factors for New Certified Residential Wood Heaters

Residential Wood Combustion Technology Review

Residential Wood Combustion Technology Review - Volume 2. Appendices

Emission Factors for New Certified Residential Wood Heaters

Review of Wood Heater and Fireplace Emission Factors

Verification of Emission Factors for U.S. EPA Certified Wood Heaters

Design and Operating Factors Which Affect Emissions from Residential Wood-Fired Heaters: Review and Update

Discussion Regarding Reporting Units for Emissions from Residential Cord-wood Burning Space-heating Appliances

Oregon's Woodstove Certification Program (1985)

Woodstove Emission Measurement Methods: Comparison and Eimission Factors Update

Summary Report of the In Home Emissions and Efficiency Performance of Five Commercially Available Masonry Heaters

Field Performance of Woodburning Stoves in Crested Butte, Colorado

Defining Masonry Heaters - A Discussion Paper

Colorado Regulation No. 4

EPA Method 5G

R-2000 Makeup Air Guidelines

Investigation of Negative Pressure Test Protocols for Wood- and Pellet-Burning Appliances

Fireplace Air Requirements

Modifications and Refinement of the Computer Model "Wood Burning Simulator"

The Dynamics of Domestic Open Fires

The Flow of Gases in Furnaces (1923)

Recent Laboratory and Field Testing of Masonry Heater and Masonry Fireplace Emissions

The Hearth as an Element of the Sustainable House - A Comparison of Emission Test Methods for New Clean Burning Wood Fired Masonry Fireplaces

Low Emisson and High Efficiency Residential Pellet-Fired Heaters

Design, Construction and Performance of Stick-Wood Fired Furnace

Flue Gas Emissions in Wood Burning Stoves

Determination of Condensible Particulate Woodstove Emission Factors Using Condar's Emissions Sampler

Calibration of 4 Condar Portable Dilution Tunnels

Canterbury method 1 for testing of ultra-low emission wood heaters

Environment Canterbury, New Zealand, 2015 PDF: NZ Canterbury method uleb-appendix-1.pdf

Real-life Emissions Testing of Pellet Burners in Tokoroa

Ministry of the Environment, New Zealand, 2007 PDF: emissions-testing-pellet-burners-tokoroa-jun...

Real-life Emissions Testing of Wood Burners in Tokoroa

Ministry of the Environment, New Zealand, 2007 PDF: emissions-testing-wood-burners-tokoroa-jun07...

Real Life Emissions Testing of Pre 1994 Woodburners in New Zealand

Environment Waikato, New Zealand, 2006 PDF: tr0605.pdf

Real-life emissions from residential wood burning appliances in New Zealand

A.J. Scott, Environment Canterbury, 2005 PDF: air-report-emissions-residential-wood-burning-appl...

Fireplaces: Studies in Contrasts

Reproduced from a now-dead copy on HearthNet Editors Note [from HearthNet]: The following articl...

Strawbale Moisture Sensor Study

Archived for Canada Mortgage and Housing Corporation, Division of Building Research

1993-1995 Seattle Testing: "Very Low Emissions Cordwood Combustion in High Burn Rate Appliances - Early Results with Possible Implications"

Ancient PDF Download: p-awma2-2.PDF

High Performance Masonry Heating

Stephen BushwayDeer Hill Masonry Heat224 West StreetCummington, MA 01026-9643413.634.0029   (Th...

Woodburning, forestry and global warming

This paper was written for the 1993 Air and Waste Management Association annual conference by Dr....