HK-K16 - February 5th, 2009
Notes
- Warm heater
- White Birch, 20% moisture
- 9 pieces, 4.5 lbs kindling, 63.6 lbs total
- Smaller pieces, kindling stacked tighter than HK-K15, to slow down start
- Slower start. CO and PM spikes, delayed and smaller than HK-K15.
- Air left open, flue damper left open. Data collection stopped at 120 minutes.
- Very low efficiency at the end, which reduced overall average to 70.0%, slightly lower than others
- This is a reference run to get surface temperature data for a cycle with damper open plus ashbox door open (worst case).
- 1.12 g/kg PM (Condar)
- 24.99 g/kg CO
- 70.0 % overall efficiency
Animation
Flue Gas
Air left open, data stopped at 120 minutes. Extended data is available in Excel file, below.
Slow, clean start. Delayed spikes, lower spikes. Compare with yesterday (HK-K15).
Opacity
Slightly less than yesterday, even though wood was even smaller. Due to slower start. Not enough air for large loadĀ of small wood, or firebox too small.
Statistics
Fuel stack
Resources
- Excel Data File: testo-K16.xlsm
- Condar Spreadsheet + Fueling Excel Data File: Condar-HKK-16.xlsm






No Comments