  • Warm heater
  • White Birch, 20% moisture
  • 9 pieces, 4.5 lbs kindling, 63.6 lbs total
  • Smaller pieces, kindling stacked tighter than HK-K15, to slow down start
  • Slower start. CO and PM spikes, delayed and smaller than HK-K15.
  • Air left open, flue damper left open. Data collection stopped at 120 minutes.
  • Very low efficiency at the end, which reduced overall average to 70.0%, slightly lower than others
  • This is a reference run to get surface temperature data for a cycle with damper open plus ashbox door open (worst case).
  • 1.12 g/kg PM (Condar)
  • 24.99 g/kg CO
  • 70.0 % overall efficiency
Animation

Anim-K16.gif

Flue Gas

gas-HK-K16.gif

Air left open, data stopped at 120 minutes. Extended data is available in Excel file, below.
Slow, clean start. Delayed spikes, lower spikes. Compare with yesterday (HK-K15).

Opacity

opacity-HK-K16.gif

Slightly less than yesterday, even though wood was even smaller. Due to slower start. Not enough air for large loadĀ of small wood, or firebox too small.