Skip to main content

HK-J04 - January 12th, 2008

Notes
  • Hard maple, medium pieces, 16% moisture, 56.2 lbs

  • 8 pieces, 3 lbs kindling

  • Cold fuel. Warm heater (24 hrs)

  • 0.9 g/kg PM (Condar) Note: estimated value, due to a gas leak.

Animation

Anim-J04.gif

Flue Gas

gas-HK-J04.gif

  • At 15 minutes, the pile rolls forward towards the glass.
  • At 31 minutes, the pile is poked to get the wood off the glass and towards the back of the firebox. This causes both CO and opacity to spike
  • At 53 minutes, a leak is discovered because of a loose cover on the Condar probe filter cover. This makes the gas results from 0 to 53 minutes invalid. In the Condar spreadsheet calculation, below, the gas values from run HK-H20 were pasted in from 0 to 53 minutes, in order to be able to arrive at an approximate g/kg PM number off the filter. 
  • The CO and efficiency results are not valid, because they don't account for the CO spike at 31 minutes.
Opacity

opacity-HK-J04.gif

Statistics

Condar-HK-J04.gif

Fuel stack

J04-03.jpg

HK-J04-01a.JPG

Resources