HK-H20 - March 11th, 2007
Notes
- Small to medium maple. Warm heater. 54.2 lbs
- Previous fire: 24 hours.
- Grate air open. Ashbox door open until stack temperature reached 400F (11 minutes) and then closed (air open)
- Reference run.
- This run was a best guess as to an optimum fuel loading and optimum air.
- Very clean, low PM, low CO, very good efficiency.
- The CO/CO2 ratio was the lowest recorded during the series, with a minimum of .0039 from minute 50 to minute 55
- CO bottomed out at 226 ppm, or 0.023% (at 13.2% oxygen)
- This run will serve as a benchmark for comparison for future tests.
- This concludes the HK-H test series. Next testing will be at 2007 MHA Meeting, April 13th - 19th.
Animation
2 minute intervals. 60 frames.
Flue Gas
Opacity
Fuel stack (shot late)
Resources
- Excel Data File: testoH-20.xls