Skip to main content

HK-K12 - January 19th, 2009

Notes
  • Warm heater
  • Air closed at 115 minutes. Damper cut back. Closed at 275 minutes.
  • Somewhat tight stacking, resulting in a bit of PM.
  • Large kindling, slower start.
  • White Birch, 20% moisture
  • 7 pieces, 4.5 lbs kindling, 63.0 lbs total
  • 0.89 g/kg PM (Condar)
  • 11.70 g/kg CO
  • 71.7 % overall efficiency
Animation

Anim-K12.gif

Yellow flames that are not real hot look a lot redder with a digital camera, which is very sensitive in the near-infrared range.

Flue Gas

gas-HK-K12.gif

Notice the very even oxygen curve, lacking a dip at the beginning, and a corresponding CO spike. Poke at 55 minutes. Largest bottom piece placed on top, so that it will burn with the others.

Opacity

opacity-HK-K12.gif

Statistics

Condar-HK-K12.gif

Fuel stack

K12-01.jpg

K12-00.jpg

Resources
  • Excel Data File: Unavailable
  • Condar Spreadsheet + Fueling Excel Data File: Condar-HKK-12.xlsm