Skip to main content

HK-H18 - March 10th, 2007

Notes
  • Large maple. Medium warm heater. 49lbs
  • Previous fire: 36 hours.
  • Grate air closed. Ashbox door open (similar to old HeatKit air)
  • Slow start after kindling burned.
  • Low opacity (particulates), medium CO, medium efficiency.
  • For a lukewarm heater with this air supply, the fuel was too large for the load size. A better burn would be had with smaller fuel, or more fuel.
Animation

Anim-H18.gif

2 minute intervals.

Flue Gas

gas-HK-H18.gif

Opacity

opacity-HK-H18.gif

  • Ohm reading: 250 start, 261 finish. Likely 11 ohm drift from deposit on the mirror, or lamp fading.
  • At 24 minutes, reading was 273 ohms, and a very slight amount of blue smoke was visible from chimney exit.
  • At 34 minutes, reading was 265 ohms, and no smoke was visible.
Fuel stack

H18-01.jpg

Resources