HK-H18 - March 10th, 2007
Notes
- Large maple. Medium warm heater. 49lbs
- Previous fire: 36 hours.
- Grate air closed. Ashbox door open (similar to old HeatKit air)
- Slow start after kindling burned.
- Low opacity (particulates), medium CO, medium efficiency.
- For a lukewarm heater with this air supply, the fuel was too large for the load size. A better burn would be had with smaller fuel, or more fuel.
Animation
2 minute intervals.
Flue Gas
Opacity
- Ohm reading: 250 start, 261 finish. Likely 11 ohm drift from deposit on the mirror, or lamp fading.
- At 24 minutes, reading was 273 ohms, and a very slight amount of blue smoke was visible from chimney exit.
- At 34 minutes, reading was 265 ohms, and no smoke was visible.
Fuel stack
Resources
- Excel Data File: testoH-18.xls
- Fueling Excel Data File: fueling-07-HK18.xls




No Comments