HK-J23 - February 15th, 2008
Notes
- Lowest CO of 30 run series
- White birch, 20% moisture, 70.5 lbs
- Very large pieces, smaller on top, 7 pieces
- Stack sloped towards kindling
- Warm heater (137F firebox temp), warm fuel
- Side ignition.
- Cold kindling, false start, needed boost with torch
- Last 10 minutes of gas data lost - substituted with estimated data.
- Very low CO.
- 0.8 g/kg PM (Condar)
- 13.7 g/kg CO
- 73.0% overall efficiency
- Very large log #1 (bottom right), 14.2 lbs - required repositioning at the end to burn.
Animation
Last 10 minutes missing.
Flue Gas
Computer crash, last 10 minutes of gas data lost - substituted with estimated data.
Very low CO. Lowest CO/CO2 ratio recorded to date, 0.0010, around 60 minutes.
Opacity
Statistics
Fuel stack
Piece #1 on far left.
Resources
- Excel Data File: testoJ-23.xls
- Condar Spreadsheet + Fueling Excel Data File: Condar-HKJ-23.xls






No Comments