Skip to main content

HK-J23 - February 15th, 2008

Notes
  • Lowest CO of 30 run series
  • White birch, 20% moisture, 70.5 lbs
  • Very large pieces, smaller on top, 7 pieces
  • Stack sloped towards kindling
  • Warm heater (137F firebox temp), warm fuel
  • Side ignition.
  • Cold kindling, false start, needed boost with torch
  • Last 10 minutes of gas data lost - substituted with estimated data.
  • Very low CO.
  • 0.8 g/kg PM (Condar)
  • 13.7 g/kg CO
  • 73.0% overall efficiency
  • Very large log #1 (bottom right), 14.2 lbs - required repositioning at the end to burn.
Animation

Anim-J23.gif

Last 10 minutes missing.

Flue Gas

gas-HK-J23.gif

Computer crash, last 10 minutes of gas data lost - substituted with estimated data.
Very low CO. Lowest CO/CO2 ratio recorded to date, 0.0010, around 60 minutes.

Opacity

opacity-HK-J23.gif

Statistics

Condar-HK-J23.gif

Fuel stack

J23-02.jpg

J23-01.jpg

Piece #1 on far left.

Resources