HK-K14 - February 3rd, 2009

Notes
  • Warm heater
  • White Birch, 20% moisture
  • 6 pieces, 4.5 lbs kindling, 62.3 lbs total
  • Two large logs on bottom.
  • Air closed at 100 minutes with glowing coal bed.
  • Flue damper left open.
  • 1.02 g/kg PM (Condar)
  • 15.86 g/kg CO
  • 71.3 % overall efficiency
Animation

Anim-K14.gif

Flue Gas

gas-HK-K14.gif

Air closed at 100 minutes, flue damper left open. Testo data from 1-100 minutes used for stack loss and emissions calculations. Testo probe pulled at 120 minutes. Note CO, O2 and stack temperature returning to ambient conditions.

Opacity

opacity-HK-K14.gif

Statistics

Condar-HK-K14.gif

Fuel stack

K14-00a.jpg

K14-00.jpg

Resources
  • Excel Data File: Unavailable
  • Condar Spreadsheet + Fueling Excel Data File: Condar-HKK-14.xlsm