HK-H11 - March 1st, 2007
Notes
- Small maple. 19% moisture (estimated)
- 9 pieces, stacked 3221. Left side ignition.
- Cold heater. Damper left open since last night.
- New prototype air system - modified Frishch-Rosin - two one inch pipes (photo to follow)
- It didn't make much difference at the end of the burn. At the beginning, it was a good way to generate smoke (see graphs, where air system was switched in briefly a few times, shown by the big flue temperature dips)
- Animated Gif below, taken at 2 minute intervals.
- Opacity normalized to a 1 - 100 scale. Not directly comparable with graphs prior to HK-H09.
Experimental air system, based on the Frisch Rosin system for fireplace (two 1" pipes). In this case,
the location of the two inlets is changed as shown.
Animation
Flue Gas
Large dips in flue temperature correspond to prototype air system. Huge opacity spikes for first two (see below),
Only small spikes later.
Opacity
The flashlight from HK-H09 has been replaced with a 50 watt halogen bulb.
Ohm readings off CdS sensor normalized to 0 - 100% opacity.
Fuel stack
Resources
- Excel Data File: testoH-11.xls
- Fueling Excel Data File: fueling-07-HK11.xls