HK-J12 - January 27th, 2008

Notes
  • Highest PM number of 30 run series
  • Highest Surface/Volume of 30 run series
  • Lowest moisture of 30 run series
  • OMNI ASTM fuel crib, 10% moisture 47.2 lbs
  • 12 pieces, 6 lbs kindling
  • Room temp fuel. Warm heater (24 hrs)
  • Kindling from the bottom (underneath pile)
  • Modified air - front slot reduced 50%
  • 3.6 g/kg PM (Condar)
  • 36.5 g/kg CO
  • 74.7 % overall efficiency
  • Compare with crib tests HK-H13, and HK-H12
Animation

Anim-J12.gif

Flue Gas

gas-HK-J12.gif

Opacity

opacity-HK-J12.gif

Statistics

Condar-HK-J12.gif

Fuel stack

J12-002.jpg

Fuel cribs

J12-001.jpg

Fuel cribs. The two rightmost cribs were used for this test, with the smaller kindling crib underneath