Skip to main content
HK-J05 - January 13th, 2008
Notes
- Hard maple, medium pieces, 16% moisture, 52 lbs
- 8 pieces, 3.6 lbs kindling
- Cold fuel, stacked in warm firebox for 4 hours. Warm heater (24 hrs)
- 0.8 g/kg PM (Condar)
- 27.0 g/kg CO
- 75.8 % overall efficiency
Animation

Flue Gas

- Ashbox door closed (air cut back) when stack temperature reached 300F (35 minutes). Both bells were open (slower rise in stack temp)
- Spikes in stack temp after 85 minutes correspond to pokes.
- A repeat of the last run (similar to reference run HK-H20), except pile did not fall towards glass.
- Also, gas data for run HK-J04 was estimated.
Opacity

Statistics

Fuel stack


Resources
No Comments